Center News
-
Hao Zhang — ConvLSTM-based modeling of magnetic domain evolution in electric motor core materials
A sequence of Kerr images helps predict which magnetic domains will grow or shrink as the applied field changes.
-
Yupeng Chen — Effect of Al₂O₃ Content on the High-Frequency Magnetic Properties of Fe-Si Soft Magnetic Composites Prepared by SPS
Alumina insulates Fe–Si particles against eddy currents, while the amount added also affects how much permeability the core retains.
-
Rawal Shahbaz — Magnetic Domain Pattern and Characteristic Deterioration of Electrical Steel Due to Laser Cutting
Local hysteresis measurements trace how magnetic properties recover with distance from a laser-cut edge.
-
Xiaotong Wang — An integrated approach for magnetostriction measurement and simulation of nanocrystalline alloys in high-frequency transformers
A double-yoke fixture and laser vibrometer resolve the small cyclic strains that contribute to vibration in high-frequency transformer cores.
-
Wenbin Meng — Magnetic measurement and analysis of nanocrystalline laminates with different dimensions
Laminates made from the same batch of nanocrystalline ribbon can show different losses at the same frequency and peak flux density.
-
Shuai Zhao — Angle-compensated non-invasive current measurement of multi-conductor cables via a TMR sensor-array
A ring of magnetic sensors separates the contributions of three conductors to the field measured outside a cable.
-
Ziyang Wang — Power-frequency magnetoelectric energy harvester using FeCoV–PZT laminates based on ericsson cycle
A tip magnet tunes a magnetoelectric cantilever to the 50 Hz range for harvesting energy from stray transformer fields.
-
Rawal Shahbaz — Quantifying magnetic degradation in laser-cut electrical steel: A domain-level study with angle-dependent magnetization
In laser-cut electrical steel, the increase in local hysteresis loss near the edge depends on the direction of magnetization.
-
Tao Chen — Study on Electromagnetic Vibration Characteristics of Anode Saturable Reactor Considering Anisotropic Properties
A coupled magnetic and mechanical model retained the directional properties of the core steel. Measured vibration modes and velocities tested its predictions, with an experimental-to-simulation discrepancy below 10%.
-
Ziran Guo — An improved J-A model for iron-based soft magnetic composites considering local demagnetization effect
Accounting for the demagnetizing field within powder cores improved the near-saturation prediction. Relative errors in the loop and loss comparisons were below 8% over 10–100 Hz.
-
Guotao Sun — Analysis of magnetic domain evolution in rotational magnetization of GOES based on morphological characteristics and artificial neural network
Tracking domain shapes as the field rotated identified the seventh Hu moment as a particularly sensitive indicator of magnetization.
-
Wenbin Meng — Comparison of micromagnetic modeling and experiment considering grain size distribution at 1–20 kHz
A three-dimensional model built from the measured grain-size distribution reproduced loss density and coercivity with average deviations below 10%.
-
Tao Chen — Measurement and Analysis of the Magnetostriction of Oriented and Non-Oriented Electrical Steel Sheets
A single-sheet tester and laser interferometer measured magnetic induction and magnetostrictive strain together from 50 Hz to 2.5 kHz.
-
Guochen Niu — Testing of magnetic properties of amorphous and nanocrystalline alloys applied out-of-plane stress at wide frequency range
The same loading fixture revealed different loss trends in two core materials. Normal stress increased loss in the nanocrystalline samples, while the amorphous samples showed a nonmonotonic response above the kilohertz range.
-
Haitao Zhang — Measurement and analysis of magnetostriction of nanocrystalline alloy laminations under medium-frequency excitation
Between 1 and 10 kHz, the hysteresis loops widened, while peak-to-peak magnetostriction first rose and then fell. The measured strain also changed from elongation to contraction.
-
Ziran Guo — High performance soft magnetic composites based on Fe/Ni-Zn ferrite powder prepared by low-pressure spark plasma sintering
Of four ferrite contents tested, 2.5 wt% gave the best overall magnetic performance in the iron powder cores at 20–200 kHz.
-
Kai Wang — Optimal Design of Hybrid Laminated Core for Power Transformer
Moving a steel grade from one layer of a transformer core to another changes the flux distribution. The authors compared several arrangements in three-dimensional transient simulations to identify the lower-loss configuration.
-
Yifan Chen — Data-Driven Deep Convolutional Neural Networks for Electromagnetic Field Estimation of Transformers
The researchers encoded permeability, conductivity and excitation current in separate input channels and compared them with a grayscale representation. Two-dimensional finite-element solutions provided the reference fields.
-
Hao Zhang — Temperature-dependent hysteresis model based on temporal convolutional network
Measurements on N87 ferrite covered 25–125 °C and 5–20 kHz. The model used the temperature dependence of spontaneous magnetization to predict how its hysteresis loops and losses changed.
-
Wenbin Meng — High-frequency loss modeling of nanocrystalline core considering nonuniform distribution of flux density
Wound cores with the same average flux density can have different local flux distributions. Allowing for that variation brought the average loss-calculation error within 10% for the tested core thicknesses.
-
Hao Zhang — Magnetic Properties Simulation of Electrical Steel Sheet Based on Recurrent Neural Network
Harmonics change both the shape and area of the hysteresis loop in electrical steel. In the harmonic tests reported in the paper, the recurrent model predicted total loss with an error below 3%.
-
Haoran Li — Harmonic and DC Bias Hysteresis Characteristics Simulation Based on an Improved Preisach Model
DC bias makes the hysteresis loop of grain-oriented steel asymmetric. The team used measured limiting loops to generate first-order reversal curves and construct Everett functions for different bias fields. Measurements under harmonic excitation and DC bias were used to test the model.
-
Min Zhang — Measurement and Simulation of Magnetic Properties of Nanocrystalline Alloys under High-Frequency Pulse Excitation
With the pulse voltage held constant, increasing the repetition rate or reducing the duty cycle narrowed the measured minor hysteresis loops. At 1 kHz the field–circuit simulation showed the core reaching saturation after five pulses at 5% duty and nine pulses at 1% duty.
-
Baichuan Yu — Simplified Calculation Model for Contact Resistance Based on Fractal Rough Surfaces Method
The apparent contact area of two conductors hides the small patches that actually carry current. A statistical model links those patches and a surface film to contact resistance. Among the surfaces studied at a given load, a fractal dimension of 1.5 gave the lowest resistance.
-
Yan Zhang — Magnetic properties deterioration of non-oriented steel due to laser cutting
How far does the effect of a laser cut extend into a motor lamination? Local hysteresis measurements on 35WW250 electrical steel detected magnetic degradation as far as 18 mm from the cut edge. Magneto-optical images showed how the domain pattern changed across the same region.
-
Lan Yang — Punching effects on local magnetic properties near the edge of nonoriented electrical steels
A miniature B–H sensor mapped magnetic damage inward from a punched edge. In sheets punched at 80 and 250 MPa, the affected regions extended about 6 and 12 mm from the edge, respectively. Local loss measurements showed how much of the increase came from hysteresis and excess loss.
-
Yakun Tian — Modeling and Validation of Stray-Field Loss in Laminated Magnetic Shield of Transformer under Harmonics and DC Bias
A modified TEAM P21 benchmark provided a common test for measured and calculated losses in a laminated transformer shield. For cases III and IV, using magnetic properties measured under the actual nonsinusoidal excitation reduced the loss errors from 6.17% and 7.00% to 2.36% and 2.93%, respectively.
-
Yifan Chen — Thermal Network Model of High-Power Dry-Type Transformer Coupled With Electromagnetic Loss
A thermal network divided the windings of a 2,500 kVA dry-type transformer into 11 regions and accounted for differences in electromagnetic loss and cooling along the ducts. The temperature-rise study located the hot spot at the top of the outermost high-voltage winding, at 151.8 °C.
-
Jiajun Wang — Dynamic Core Loss Simulation of the Anode Saturable Reactor of UHVDC Converter Valves
When a converter valve switches, the current pulses drive more loss in the reactor core than a sinusoidal excitation. The researchers measured the properties of ultra-thin silicon steel, modeled the eddy currents near the core gap and checked their loss calculation against a reactor temperature-rise test. The mean housing temperature reached 76 °C.
-
Yifan Chen — Magnetic-Thermal Coupling Analysis of Saturable Reactor
The hottest part of a converter-valve reactor can be hidden inside its core. Mapping the spatial distribution of core loss into a fluid and thermal model gave a simulated hot spot of 117.4 °C inside the core and 80.5 °C on the inner toroidal surface. Temperature measurements provided an experimental check.
-
Xinxiao Yan — Numerical Prediction of Losses and Local Overheating in Transformer Windings Based on Magnetic-Thermal-Fluid Model
Leakage flux heats some parts of a foil winding more than others. For a 2,500 kVA dry-type transformer, the team mapped the electrical loss in each mesh element into the thermal model and accounted for the effect of temperature on losses. Under rated load, the predicted values agreed with the temperature-rise test to within ±6%.
-
Xinxiao Yan — Prediction of temperature rise for ventilated dry-type transformer by 3-D coupled magneto-fluid-thermal model
Cooling air follows different paths along the height of a ventilated transformer. The team modeled the foil-winding eddy currents, directional core losses and airflow around the winding supports. On a 2,500 kVA unit, predicted temperature rises were within 7% of the measurements at the sampled winding positions.
-
Xinxiao Yan — Eddy Current Loss Effect in Foil Winding of Transformer Based on Magneto-Fluid-Thermal Simulation
An insulation barrier changes both the flow of cooling air and radiative heat exchange between transformer windings. The team compared modeled temperatures with infrared measurements on a 2,500 kVA dry-type transformer to locate hot spots in and around its foil winding.
-
Ruiying Chen — An Improved Method for Measuring the Magnetic Properties of Silicon Steel With Double Sheets at High Frequency
Placing two steel sheets in a symmetric magnetic circuit creates a gap in which a sensing coil can measure a field close to the one inside the steel. The apparatus operated at frequencies up to 20 kHz, and the paper reports hysteresis loops of ultra-thin steel at several test frequencies.
-
Xinxiao Yan — Vector Magnetic Properties Measurement of Silicon Steel Under Biased Magnetic Excitation Along Laminated Direction
A static magnetic field through a stack of electrical steel changes the in-plane response. Surface sensing coils allowed the team to measure this interaction in grain-oriented steel and use the observations to identify an anisotropic material model.
-
Qingxin Yang — Measurement and Modeling of Rotational Hysteresis Loss of Electric Soft Magnetic Material
Rotating flux in a motor or transformer can follow an ellipse whose axes change during a cycle. The researchers separated tangential and radial contributions to hysteresis loss and compared the resulting predictions with measurements under four excitation patterns.
-
Qingxin Yang — An Electromagnetism Simulation Methodology of Laminated Silicon Steel by Three Axes Orthogonal and Wide Frequency Excitation
Measurements from 20 Hz to 1 kHz provided a test for two descriptions of laminated steel. A linear analytical model reproduced weak-field behavior, while a nonlinear finite element model separated the eddy-current paths at stronger fields.
-
Yongjian Li — An Electromagnetic Simulation Method Considering Hysteresis and Micro-Eddy Current Effect
Treating laminated steel as a solid core simplifies the mesh but obscures microscopic eddy currents. The researchers coupled an inverse Preisach model to the field equations and tested it against alternating and rotating magnetization measurements on 35WW270 steel.
-
Yongjian Li — Measurement of Three-Dimensional Magnetic Properties With Feedback Control and Harmonic Compensation
Deep saturation makes the flux trajectory hard to control when electrical steel is magnetized along several axes. The authors combined frequency-domain feedback, harmonic compensation and paired clockwise and counterclockwise tests to obtain more reliable rotational-loss measurements.